linux:centos:software-raid1-setup
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
linux:centos:software-raid1-setup [2020/04/22 20:58] – [Replace a failed hard disk in raid setup] odefta | linux:centos:software-raid1-setup [2025/01/02 20:22] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 111: | Line 111: | ||
Suppose the /dev/sdb hard disk failed. \\ | Suppose the /dev/sdb hard disk failed. \\ | ||
- | To replace it with a good hdd, set it as failed and remove it from raid array: | + | To replace it with a good hdd, set it as failed and remove it from the array: |
< | < | ||
mdadm /dev/md0 --fail /dev/sdb --remove /dev/sdb | mdadm /dev/md0 --fail /dev/sdb --remove /dev/sdb | ||
Line 118: | Line 118: | ||
Add the new device to the array: | Add the new device to the array: | ||
< | < | ||
- | mdadm --add /dev/md0 /dev/sdb1 | + | mdadm --add /dev/md0 /dev/sdb |
</ | </ | ||
+ | |||
+ | ==== Re-add a good hard disk (after cable disconnection for example) ==== | ||
+ | |||
+ | After reinserting the hard disk, it may be mounted now on a different device letter.\\ Ckeck it by running: | ||
+ | |||
+ | < | ||
+ | fdisk -l | ||
+ | </ | ||
+ | |||
+ | Output: | ||
+ | < | ||
+ | ... | ||
+ | Disk /dev/sdd: 4000.8 GB, 4000787029504 bytes, 7814037167 sectors | ||
+ | Units = sectors of 1 * 512 = 512 bytes | ||
+ | Sector size (logical/ | ||
+ | I/O size (minimum/ | ||
+ | </ | ||
+ | |||
+ | After identifying it, re-add it to the raid array with: | ||
+ | |||
+ | < | ||
+ | mdadm --manage /dev/md0 --add /dev/sdd | ||
+ | </ | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
+ | |||
linux/centos/software-raid1-setup.1587578322.txt.gz · Last modified: 2023/07/04 19:36 (external edit)